Cluster Server System Requirements
home ) high availability ) cluster server ) cluster server system requirements
 
cluster server quickstart system requirements
HP-UX
CD-ROM Drive
  • One CD-ROM drive on each system
Configuration
  • A minimum of 2 nodes per cluster
  • Dual heartbeats between nodes (two Ethernet hubs or crossover cables)
  • A maximum of eight network channels and four communication disks
  • Shared disk (dual ported, multi-initiated) - shared nothing configurations are supported but replication or synchronization of data between nodes is required 
Disk Space
  • Each VERITAS Cluster Server system must have at least 35 megabytes of free disk space
Disks
  • Typical configurations require shared disks to support applications that migrate between nodes
Ethernet Controllers
  • Requires at least one Ethernet controller per node in addition to the built-in public Ethernet controller
HP-UX Supported Server Hardware
  • HP 9000: D, K, L, N, R, V classes
HP-UX Supported Storage Hardware
  • HP AutoRaid
  • HASS
  • DG Clariion - SCSI 1000 3000
  • HP-branded DG Clariion
  • EMC Symmetrix - 37xx XP256, XP512
Networking
  • Public Network: 10-MB/100-MB/Gigabit Ethernet
  • Private Network: 10-MB/100-MB Ethernet 
SCSI Adapters
  • Requires at least one built-in SCSI adapter per system for the operating system disks and at least one additional SCSI adapter per system for shared data disk
Servers
  • Two or more HP/9000 D, K, L, N, R, V class serv
VERITAS Cluster Server Systems
  • HP-UX 11.0, 32 and 64 bit
  • Each VERITAS Cluster Server system must have at least 35 megabytes of free disk space
  • Each VERITAS Cluster Server system requires at least 128 MB RAM

Microsoft Windows NT Enterprise Edition
CD-ROM Drive
  • One CD-ROM drive on each system
Configuration
  • A minimum of 2 nodes per cluster
  • Dual heartbeats between nodes (two Ethernet hubs or crossover cables)
  • A maximum of eight network channels and four communication disksShared disk (dual ported, multi-initiated) - shared nothing configurations are supported but replication or synchronization of data between nodes is required
Disks
  • Typical configurations require shared disks to support applications that migrate between nodes
Ethernet Controllers
  • Requires at least one Ethernet controller per node in addition to the built-in public Ethernet controller
Networking
  • Public Network: 10-MB/100-MB/Gigabit Ethernet
  • Private Network: 10-MB/100-MB Ethernet
SCSI Adapters
  • Requires at least one built-in SCSI adapter per system for the operating system disks and at least one additional SCSI adapter per system for shared data disk
Servers
  • Dell 2300 PowerEdge, Compaq Proliant 1850K 
Supported Server & Storage Hardware
  • Servers
    Dell 2300 PowerEdge, Compaq Proliant 1850K, IBM Netfinity, HP Netserver, and many more
  • Storage
    JBOD
    Storage Works
    HDS
    FC JBOD (Clariion FC5500)
    EMC Symmetrix 
VERITAS Cluster Server Systems
  • Windows NT: 4.0 Server or Enterprise Edition with SP6a
  • Each VERITAS Cluster Server system must have at least 35 megabytes of free disk space
  • Each VERITAS Cluster Server system requires at least 128 MB RAM 

Microsoft Windows NT Server
CD-ROM Drive
  • One CD-ROM drive on each system
Configuration
  • A minimum of 2 nodes per cluster
  • Dual heartbeats between nodes (two Ethernet hubs or crossover cables)
  • A maximum of eight network channels and four communication disks
  • Shared disk (dual ported, multi-initiated) - shared nothing configurations are supported but replication or synchronization of data between nodes is required
Disks
  • Typical configurations require shared disks to support applications that migrate between nodes
Ethernet Controllers
  • Requires at least one Ethernet controller per node in addition to the built-in public Ethernet controller
Networking
  • Public Network: 10-MB/100-MB/Gigabit Ethernet
  • Private Network: 10-MB/100-MB Ethernet
SCSI Adapters
  • Requires at least one built-in SCSI adapter per system for the operating system disks and at least one additional SCSI adapter per system for shared data disk
Servers
  • Dell 2300 PowerEdge, Compaq Proliant 1850K
Supported Server & Storage Hardware
  • Servers
    Dell 2300 PowerEdge, Compaq Proliant 1850K, IBM Netfinity, HP Netserver, and many more
  • Storage
    JBOD
    Storage Works
    HDS
    FC JBOD (Clariion FC5500)
    EMC Symmetrix 
VERITAS Cluster Server Systems
  • Windows NT: 4.0 Server or Enterprise Edition with SP6a
  • Each VERITAS Cluster Server system must have at least 35 megabytes of free disk space
  • Each VERITAS Cluster Server system requires at least 128 MB RAM
Windows NT Supported Server Hardware
  • Dell 2300 PowerEdge, Compaq Proliant 1850K, IBM Netfinity, HP Netserver, and many more
Windows NT Supported Storage Hardware
  • JBOD
  • Storage Works
  • HDS
  • FC JBOD (Clariion FC5500)
  • EMC Symmetrix

Sun Solaris
CD-ROM Drive
  • One CD-ROM drive on each system
Configuration
  • A minimum of 2 nodes per cluster
  • Dual heartbeats between nodes (two Ethernet hubs or crossover cables)
  • A maximum of eight network channels and four communication disks
  • Shared disk (dual ported, multi-initiated) - shared nothing configurations are supported but replication or synchronization of data between nodes is required
Disk Space
  • Each VERITAS Cluster Server system must have at least 35 megabytes of free disk space
Disks
  • Typical configurations require shared disks to support applications that migrate between nodes
Ethernet Controllers
  • Requires at least one Ethernet controller per node in addition to the built-in public Ethernet controller
Memory
  • Each VERITAS Cluster Server system requires at least 128 MB RAM
Networking
  • Public Network: 10-MB/100-MB/Gigabit Ethernet
  • Private Network: 10-MB/100-MB Ethernet
SCSI Adapters
  • Requires at least one built-in SCSI adapter per system for the operating system disks and at least one additional SCSI adapter per system for shared data disk
Servers
  • Two or more SPARC/Solaris servers
Solaris Supported Storage Hardware
  • Sun StorEdge models
  • DG Clarion: SCSI, FC 5x00, FC 3x00 (no split bus)
  • Compaq StorageWorks: RA7000, ESA 10000
  • EMC: Symmetrix
  • Hitachi Data Systems: 5800 SCSI/FC, FC 7700E
  • HP: XP256, XP512
  • Network Appliance Series 700 Filers
Solaris Supported Server Hardware (SBUS)
  • Sparc 5, 10, 20, 1000
  • Ultra 1, 2
  • E3x00, 4x00, 5x00, 6x00
  • SC2000, E10000 PCI
  • Ultra 5, 10, 30, 60, Netra T, E220/250, E420/450
Supported Server & Storage Hardware
  • Servers
    SBUS:
    Sparc 5, 10, 20, 1000
    Ultra 1, 2
    E3x00, 4x00, 5x00, 6x00
    SC2000, E10000 PCI
    Ultra 5, 10, 30, 60, Netra T, E220/250, E420/450
  • Storage
    Sun StorEdge models
    DG Clariion: SCSI, FC 5x00, FC 3x00 (no split bus)
    Compaq StorageWorks: RA7000, ESA 10000
    EMC: Symmetrix
    Hitachi Data Systems: 5800 SCSI/FC, FC 7700E
    HP: XP256, XP512
    Network Appliance Series 700 Filers
VERITAS Cluster Server Systems
  • Solaris: 2.5.1 or later
  • Each VERITAS Cluster Server system must have at least 35 megabytes of free disk space
  • Each VERITAS Cluster Server system requires at least 128 MB RAM


 
 


Veritas Elite Partner in the UK for disaster recovery, backup software, data protection, data management, storage management and application performance products, services and solutions from Q Associates UK


HomeApplication PerformanceData ManagementData ProtectionDisaster RecoveryEmail ManagementHigh AvailabilityServer ProvisioningCase StudiesSymantec ConsultancyRequest PricingRequest InformationAbout Q AssociatesServicesPartnersQ NewsRelated LinksSite Map

Q Associates
Langley Business Court, Beedon, Newbury, Berkshire, RG20 8RY, UK.
E-mail: info@qassociates.co.uk I Tel: +44 (0)1635 248 181 I Fax: +44 (0)1635 247 616